Drainage and Utilities CONNECT Edition Help

Grating Parameters (United Kingdom) Dialog Box

For Grating inlet types, a numerical value for Grating Parameter (Gd) is associated with each Grating Type. This parameter is used in computing efficiency of a Grating inlet

This dialog allows you tp specify the grating parameters for each grating type.

The dialog box contains the grating type vs. grating parameter table and the following controls:

Setting Description


New
This button creates a new row in the type-parameter table.


Delete
This button deletes the currently highlighted row from the type-parameter table.


Report
Opens a print preview window containing a report that details the input data for this dialog box.

The table contains the following columns:

Column Description
Grating Type Select the grating type to be defined.
Grating Parameter Enter the parameter for the associated grating type.
Typical range of Grating Parameter values, by Grating Type, are given in the following table:
Grating Type P Q R S T
Range if G(s/m2) < or = 30 30.1 - 45 45.1 - 60 60.1 - 80 80.1 - 110
Design value Gd 30 45 60 80 110